Quick answer: pick by temperature
- Up to 200°C: silicone rubber. Flexible and economical. Some fiberglass-braided silicone constructions are rated higher.
- Up to 250°C, or where oils and chemicals are present: FEP or PTFE.
- 500°C–650°C: mica tape under a fiberglass braid.
- Up to 1,000°C: mica wire with a nickel conductor, kept to the hot zone.
These are continuous ratings for the wire itself. Measure the real temperature where the wire runs before you choose; see how hot does lead wire actually get.
The four insulations compared
Temperature ranges and examples come straight from our catalog.
| Insulation | Rated temperature | Flexibility | Abrasion | Chemicals and oils | Moisture | Relative cost | Typical uses |
|---|---|---|---|---|---|---|---|
| Silicone rubberSW-UL3132-16-500, SW-YGZ-14-4C-500 | 150°C–200°C | Very flexible | Low: cuts and tears easily | Good for water, ozone and UV; oils and fuels swell it | Good | Low | Appliances, lighting, heaters, motors |
| Silicone + fiberglass braidSW-UL3068-14-500, SW-UL3069-16-500 | 150°C–250°C | Flexible | Better: the braid takes the wear | As silicone | The braid can wick moisture | Low to medium | Ovens, furnace leads, sparks and heat splash |
| FEPSW-UL1901-20-500, SW-FF46-1-18-500 | 200°C | Moderate (more pliable than PTFE) | Good | Excellent | Excellent | Medium | Instruments, sensors, chemical plants |
| PTFESW-AF250-18-500, SW-AFR250-18-500 | 250°C | Stiffer | Good | Excellent | Excellent | High | Aerospace, semiconductor, 250°C leads |
| Mica tape + fiberglassSW-GN500-18-500, SW-GN800-16-500 | 500°C–650°C | Limited: route it once, don't flex it | Fair (braid) | Fair | Keep dry: the braid is porous | High | Kilns, furnaces, fire-resistant circuits |
| Mica, nickel conductorSW-NIMICA-1000C | 1,000°C | Limited | Fair (braid) | Fair | Keep dry | Highest | 1,000°C hot zones, short runs |
Every wire, rung by rung: the lead wire temperature ladder (PDF).
Silicone rubber: flexible and economical
Silicone rubber stays soft from well below freezing up to its rating, so it bends easily, survives vibration and is simple to strip and terminate. It handles water, ozone and UV well. Its weak points are mechanical: it cuts and tears more easily than fluoropolymers, and oils, fuels and many solvents swell it. Details by construction and UL style: silicone cable temperature guide, and for oily or chemical environments, is silicone wire oil-resistant?
When a fiberglass braid helps (and when it doesn't)
A fiberglass braid over silicone takes the abrasion, sparks and heat splash that would damage bare silicone, which is why it is common on oven and furnace leads. Go by the rating of the finished wire: sliding a braid or sleeve over an ordinary silicone wire does not raise what the silicone underneath can stand, and in a zone that stays hot it still fails at its own limit. The braid can also wick moisture. More on this: mica wire vs fiberglass sleeving.
FEP and PTFE: chemical resistance and thin walls
Fluoropolymers resist almost all oils, fuels, acids and solvents, absorb practically no water and allow thin insulation walls, so the wire is smaller for the same voltage. FEP is the more pliable of the two; PTFE goes higher in temperature and costs more. Neither is as flexible as silicone. Full comparison: PTFE vs FEP wire.
Mica wire: for furnaces, kilns and fire circuits
Above the range of any polymer, the insulation has to be mineral. Mica wire wraps the conductor in mica tape and holds it with a fiberglass braid, so there is nothing organic to char. It is meant to be routed once and left in place, not flexed in service, and it should be kept dry. Our mica constructions are also used for fire-resistant circuits; see fire-resistant cable standards.
Above about 250°C, check the conductor too
Insulation is only half the story. Tinned copper suits the silicone range; hotter constructions use nickel-plated copper, and at the top of the range a nickel conductor, because copper oxidizes quickly at furnace temperatures. Nickel conducts roughly a quarter as well as copper, so keep it to the hot section. Terminals and splices have their own limits as well: your 200°C wire is only as good as its terminals.
A five-question checklist
- Temperature: the highest continuous temperature at the wire, plus a margin.
- Movement: fixed, occasional bending, or continuous flexing.
- Chemicals and moisture: oils, fuels, solvents, wash-down or condensation.
- Space and weight: thin-wall fluoropolymers save room in tight harnesses.
- Approvals: the UL style or standard your customer or market requires.
Choosing for a whole machine or furnace? The high-temperature wire selection guide covers specifications, approvals and supplier checks.
Frequently Asked Questions
Is PTFE wire better than silicone wire?
Not in every way. PTFE handles higher temperature (250°C, against 200°C for most silicone wire) and resists oils, fuels and solvents that swell silicone. Silicone is far more flexible and costs less. If the wire moves a lot and stays at or below 200°C, silicone is usually the better choice.
Can silicone wire take 250°C?
Most silicone rubber wire is rated up to 200°C. A few complete constructions are rated higher, such as our IEC 60245 fiberglass-braided silicone wire at 250°C; go by the rating of the product, not the braid. Otherwise move to PTFE (250°C) or, for higher temperatures, mica wire.
What wire should I use at 500°C?
Mica wire: mica tape insulation under a fiberglass braid. Our range is rated 500–650°C with copper-based conductors and up to 1,000°C with a nickel conductor. Polymer insulations such as silicone, FEP and PTFE fail well below 500°C.
Is fiberglass-braided wire waterproof?
No. Woven fiberglass is porous and can wick moisture, which lowers its insulating value. Keep fiberglass-braided and mica wire dry, or choose FEP or PTFE where the wire will be wet or washed down.
Is mica wire flexible?
Flexible enough to route during installation, but not made for repeated flexing. Use mica wire for the fixed run through the hot zone and change over to silicone or fluoropolymer wire where the cable has to move.
Send your spec, get a quote within 24 hours
Tell us the temperature, movement and environment. We'll recommend the insulation, size and UL style.